• SCN Tower-Type Inverter Integrated Unit (15-25kW)
  • SCN Tower-Type Inverter Integrated Unit (15-25kW)
  • SCN Tower-Type Inverter Integrated Unit (15-25kW)
SCN Tower-Type Inverter Integrated Unit (15-25kW)
SCN Tower-Type Inverter Integrated Unit (15-25kW)
SCN Tower-Type Inverter Integrated Unit (15-25kW)
+

Share

SCN Tower-Type Inverter Integrated Unit (15-25kW)

SCN Tower-Type Inverter Integrated Unit (15-25kW)

Consult now


Category:

Power-Frequency Single-Phase Inverter Control Integrated Unit

  • Product Description
  • SCN Tower-Type Inverter-Integrated Unit (15-25kW)

    Model Number SCN-15KD SCN-20KD SCN-25KD
    Rated Power 15KW 20KW 25KW
    Peak power (20 ms) 45KVA 60KVA 75KVA
    Start the motor 10HP 12HP 15HP
    Standard battery voltage 192VDC 192VDC 240VDC
    Machine dimensions (L × W × H mm) 593x370x820
    Package dimensions (L × W × H mm) 656 × 420 × 937
    Net weight (kg) 110 116 123
    Gross weight (kg) (carton packaging) 124 130 137
    Installation method Tower-style
    Input DC Input Voltage Range 10.5–15 VDC (single-cell battery voltage)
    Mains Input Voltage Range 73VAC–138VAC (110VAC) / 83VAC–148VAC (120VAC) / 145VAC–275VAC (220VAC) / 155VAC–285VAC (230VAC) / 165VAC–295VAC (240VAC)
    Mains Input Frequency Range 45Hz–55Hz (50Hz) / 55Hz–65Hz (60Hz)
    Maximum Mains Charging Current 0–20A (varies by model; maximum charging power is up to 1/4 of the rated power)
    Mains-powered charging method Three-stage (constant current, constant voltage, float charging)
    Output Inverter Output Efficiency ≥85%
    Inverter output voltage 110VAC ±2% / 120VAC ±2% / 220VAC ±2% / 230VAC ±2% / 240VAC ±2% (Battery Mode)
    Inverter output frequency 50Hz ±0.5 or 60Hz ±0.5
    Inverter output waveform Pure sine wave
    Mains power output efficiency >99%
    Mains Output Voltage Range Follow the input
    Mains power output frequency range Follow the input
    Inverter Output Waveform Distortion ≤3% (Linear Load)
    Battery mode no-load loss ≤1% of rated power
    No-load loss in mains power mode ≤2% of rated power (mains charger not operating)
    Energy-saving mode no-load loss ≤10W
    Battery Type Valve-regulated lead-acid battery Equalization charge voltage: 14.2V; Float charge voltage: 13.8V (per cell voltage)
    Custom battery Customizable charging and discharging parameters for various battery types, tailored to user requirements.
    (Charging and discharging parameters for different battery types can be set via the operation panel.)
    Protection Low-battery voltage alarm Factory default: 11V (single-cell battery voltage)
    Battery Undervoltage Protection Factory default: 10.5V (single-cell battery voltage)
    Battery Overvoltage Alarm Factory default: 15V (single-cell battery voltage)
    Battery Overvoltage Protection Factory default: 17V (single-cell battery voltage)
    Battery overvoltage recovery voltage Factory default: 14.5V (single-cell battery voltage)
    Overload Power Protection Automatic protection (battery mode), circuit breaker or fuse (mains mode)
    Inverter Output Short-Circuit Protection Automatic protection (battery mode), circuit breaker or fuse (mains mode)
    Temperature Protection >90°C (Output Off)
    Alarm A In normal operating condition, the buzzer emits no alarm sound.
    B When there’s a battery failure, voltage abnormality, or overload protection activation, the buzzer sounds four times per second.
    C When the machine is first turned on and operating normally, the buzzer will sound five times.
    Built-in solar controller (optional) Charging Mode PWM or MPPT
    Charging current 50A/100A
    Photovoltaic Input Voltage Range PWM: 240V–352V (192V system); 300V–400V (240V system) MPPT: 240V–360V (192V system); 300V–400V (240V system)
    Maximum PV Input Voltage (Voc)
    (Under minimum temperature conditions)
    PWM: 500V (240V system) / MPPT: 450V (192V system); 500V (240V system)
    Standby power consumption ≤3W
    Maximum Conversion Efficiency >95%
    Work Mode Inverter Priority / Utility Power Priority / Energy-Saving Mode (Adjustable)
    Convert time ≤4ms
    Panel display LCD
    Cooling method Smart Fan Control
    Communication feature (optional) RS485 Communication / Mobile App (WIFI Monitoring or GPRS Monitoring)
    Environment Operating temperature -10°C to 40°C

Consult now

Welcome to inquire—we’ll get back to you within one business day. Please keep an eye on your phone or email!

中企跨境-全域组件 制作前进入CSS配置样式

Contact:

Email:

Tel:

WeChat:

在线客服添加返回顶部

右侧在线客服样式 1,2,3 1

图片alt标题设置: Helpyou New Energy

表单验证提示文本: Content cannot be empty!

循环体没有内容时: Sorry,no matching items were found.

CSS / JS 文件放置地