    Model SCN-0.7KD SCN-1KD SCN-1.5KD
    Rated Power 700W 1000W 1500W
    Peak power (20 ms) 2100VA 3000VA 4500VA
    Start the motor 0.5HP 1HP 1.5HP
    Standard battery voltage 12/24VDC 12/24VDC 24/48VDC
    Machine dimensions (L × W × H mm) 340x165x283
    Package dimensions (L × W × H mm) 405x230x340 (1 unit) / 475x415x350 (2 units)
    Net weight (kg) 9.5 (1 unit) 10.5 (1 unit) 11.5 (1 unit)
    Gross weight (kg) (carton packaging) 11 (1 unit) 12 (1 unit) 13 (1 unit)
    Installation method Tower-style
    Input DC Input Voltage Range 10.5–15 VDC (single-cell battery voltage)
    Mains Input Voltage Range 73VAC–138VAC (110VAC) / 83VAC–148VAC (120VAC) / 145VAC–275VAC (220VAC) / 155VAC–285VAC (230VAC) / 165VAC–295VAC (240VAC)
    Mains Input Frequency Range 45Hz–55Hz (50Hz) / 55Hz–65Hz (60Hz)
    Maximum Mains Charging Current 0–20A (varies by model; maximum charging power is 1/4 of the rated power)
    Mains-powered charging method Three-stage (constant current, constant voltage, float charging)
    Output Inverter Output Efficiency ≥85%
    Inverter output voltage 110VAC ±2% / 120VAC ±2% / 220VAC ±2% / 230VAC ±2% / 240VAC ±2% (battery mode)
    Inverter output frequency 50Hz ±0.5 or 60Hz ±0.5
    Inverter output waveform Pure sine wave
    Municipal Power Output Efficiency >99%
    Mains Output Voltage Range 110VAC ±10% / 120VAC ±10% / 220VAC
    ±10% / 230VAC ±10% / 240VAC ±10%
    Mains power output frequency range Follow the input
    Inverter Output Waveform Distortion ≤3% (linear load)
    Battery mode no-load loss ≤1% of rated power
    No-load loss in mains power mode ≤2% of rated power (mains charger not operating)
    Energy-saving mode no-load loss ≤10W
    Battery Type Valve-regulated lead-acid battery Equalization charge voltage: 14.2V; Float charge voltage: 13.8V (per cell voltage)
    Custom battery Customizable charging and discharging parameters for various battery types, tailored to user requirements.
    (Charging and discharging parameters for different battery types can be set via the operation panel.)
    Protection Low-battery voltage alarm Factory default: 11V (single-cell battery voltage)
    Battery Undervoltage Protection Factory default: 10.5V (single-cell battery voltage)
    Battery Overvoltage Alarm Factory default: 15V (single-cell battery voltage)
    Battery Overvoltage Protection Factory default: 17V (single-cell battery voltage)
    Battery Overvoltage Recovery Voltage Factory default: 14.5V (single-cell battery voltage)
    Overload Power Protection Automatic protection (battery mode), circuit breaker or fuse (mains mode)
    Inverter Output Short-Circuit Protection Automatic protection (battery mode), circuit breaker or fuse (mains mode)
    Temperature protection >90°C (Output Off)
    Alarm A In normal operating condition, the buzzer emits no alarm sound.
    B When there’s a battery failure, voltage abnormality, or overload protection activation, the buzzer sounds four times per second.
    C When the machine is first turned on and operating normally, the buzzer will sound five times.
    Built-in solar controller (optional) Charging Mode PWM or MPPT
    Charging current 10A to 60A
    Photovoltaic Input Voltage Range PWM: 15V–44V (for 12V systems); 30V–44V (for 24V systems); 60V–88V (for 48V systems)
    MPPT: 15V–120V (for 12V systems); 30V–120V (for 24V systems); 60V–120V (for 48V systems)
    Maximum PV Input Voltage (Voc) PWM: 50V (12V/24V systems); 100V (48V system) / MPPT: 150V (12V/24V/48V systems)
    (Under minimum temperature conditions)
    Maximum PV Input Power 12V system: 140W (10A) / 280W (20A) / 420W (30A) / 560W (40A) / 700W (50A) / 840W (60A);
    24V system: 280W (10A) / 560W (20A) / 840W (30A) / 1120W (40A) / 1400W (50A) / 1680W (60A);
    48V System: 560W (10A) / 1120W (20A) / 1680W (30A) / 2240W (40A) / 2800W (50A) / 3360W (60A)
      Standby power consumption ≤3W
      Maximum Conversion Efficiency >95%
    Work Mode Inverter Priority / Utility Power Priority / Energy-Saving Mode (Adjustable)
    Convert time ≤4ms
    Panel display LCD
    Cooling method Smart Fan Control
    Communication feature (optional) RS485 Communication / Mobile App (WIFI Monitoring or GPRS Monitoring)

Consult now

Welcome to inquire—we’ll get back to you within one business day. Please keep an eye on your phone or email!

中企跨境-全域组件 制作前进入CSS配置样式

Contact:

Email:

Tel:

WeChat:

在线客服添加返回顶部

右侧在线客服样式 1,2,3 1

图片alt标题设置: Helpyou New Energy

表单验证提示文本: Content cannot be empty!

循环体没有内容时: Sorry,no matching items were found.

CSS / JS 文件放置地