• HeySun® SHS Outdoor Series — Single-Phase Hybrid Solar Inverter 3–8 kW
HeySun® SHS Outdoor Series — Single-Phase Hybrid Solar Inverter 3–8 kW
+

Share

HeySun® SHS Outdoor Series — Single-Phase Hybrid Solar Inverter 3–8 kW

HeySun SHS Outdoor single-phase hybrid inverter, 3–8 kW, IP65 wall-mount. No technical room needed; 137–750 V lithium battery, 500 V PV input.

Consult now


Category:

Residential PV System

Keywords:

  • Product Description
  • HeySun® SHS Outdoor Series — Single-Phase Hybrid Solar Inverter 3–8 kW

    Series 02 of 03 — Outdoor IP65, high-voltage lithium platform

    Model codes: HPY-SHS-3K-on / 3.6K-on / 4.2K-on / 5K-on / 6K-on / 8K-on

    Choose the outdoor single-phase series when there is no indoor technical room and the inverter has to go straight onto an exterior wall — typical for retrofits, villas and prefabricated buildings. The IP65 housing and the high-voltage lithium battery (137–750 V) keep cabling slim, efficiency high and the interior of the house untouched.

     


    System Diagram

    Product Overview

    The HeySun® SHS Outdoor Single-Phase Series is the space-saving member of the SHS hybrid family. Where the indoor series needs a dry wall and a 24 / 48 V battery bank, this series is rated IP65, designed to be wall-mounted in direct sunlight or rain, and paired with a high-voltage lithium battery — so no plant room, no indoor cabinet and no long DC run are required.

    Six power steps from 3 to 8 kW cover a single-phase household from a compact apartment installation to a large villa with heat pumps and EV charging. The unit works with high-voltage lithium batteries on a 137–750 V bus, accepts PV arrays up to 500 V and operates in grid-tied, off-grid or hybrid mode with automatic backup changeover for essential loads. Multiple units can be paralleled for higher power.

    Key Features

    🌧️ IP65 Outdoor Housing — Weatherproof, corrosion-resistant enclosure for direct exterior wall mounting; no plant room required.
    🔋 High-Voltage Lithium Platform — 137–750 V battery bus with bidirectional energy flow for high round-trip efficiency and slim cabling.
    ⚡ Bidirectional Energy Flow — Charge and discharge, import and export, all managed automatically.
    🔌 Automatic Transfer — Automatic changeover keeps essential household loads running through outages.
    📶 PV up to 500 V — Long strings and generous array sizing for the available roof area.
    👥 Parallel-Ready — Add units as the household load grows.
    🔄 Three Work Modes — Grid-tied, off-grid and hybrid, all user-configurable.
    📱 App Monitoring — Remote status and diagnosis through the HEPUYU monitoring platform.

    Technical Specifications

    ModelHPY-SHS-3K-onHPY-SHS-3.6K-onHPY-SHS-4.2K-onHPY-SHS-5K-onHPY-SHS-6K-onHPY-SHS-8K-on
    Rated AC output power3 kW3.6 kW4.2 kW5 kW6 kW8 kW
    Grid / off-grid voltage220 / 230 / 240 V, 50 / 60 Hz
    Max. PV voltage500 V
    Battery voltage137–750 V, lithium (LFP)
    Energy flowBidirectional energy storage
    Parallel operationSupported
    Work modesGrid-tied / off-grid / hybrid, user-configurable
    Ingress protectionIP65, suitable for outdoor installation

    Detailed datasheets including efficiency curves, dimensions and protection ratings are available on request.

    Battery Sizing Guide

    Platform requirements: high-voltage lithium (LFP) bank on a 137–750 V bus. Because the bus voltage is high, the DC current stays low — even the 8 kW model draws only about 20 A at full load — so a modest-capacity battery comfortably supports the rated power.

    Three-step sizing:

    1. Night-time energy = daily household consumption × night share (typically about 50%).
    2. Required capacity = night-time energy ÷ depth of discharge (0.9 for LFP) ÷ system efficiency (about 0.9).
    3. Check the discharge rate = peak load ÷ (capacity ÷ battery voltage); on this high-voltage platform the rate is rarely the limiting factor, so capacity is normally driven by the overnight energy requirement.

    Typical configuration — residential self-consumption with overnight cover:

    Model groupTypical LFP capacityTypical duty
    HPY-SHS-3K-on / 3.6K-on5 kWhSmall home, essential loads overnight
    HPY-SHS-4.2K-on / 5K-on5–10 kWhStandard family home
    HPY-SHS-6K-on10 kWhLarger home, 10–14 kWh overnight
    HPY-SHS-8K-on15–20 kWhVilla with pumps, well or EV charging

    Figures are typical reference values for self-consumption sizing, not a supply commitment; final sizing follows the load calculation for the specific site, and the selected battery must be compatible with the 137–750 V DC bus.

    PV Array Sizing Guide

    Inverter limits: maximum PV voltage 500 V on every model of this series. The per-model maximum PV input power and MPPT current limits are given in the detailed datasheets (available on request), so in practice the array is sized with the design rules below and confirmed against the datasheet at order stage.

    Three-step sizing:

    1. Required array power = daily consumption ÷ (peak sun hours × performance ratio). Take the performance ratio as 0.75–0.8 and the peak sun hours from local solar data — for example, 12 kWh ÷ (4.5 h × 0.78) ≈ 3.4 kWp.
    2. DC/AC ratio = array kWp ÷ inverter rated output. Residential practice is a ratio of about 1.1–1.3: it fills the mornings, evenings and cloudy days without wasting midday production.
    3. String design — modules in series must keep the open-circuit voltage (calculated at the coldest site temperature) below 500 V, and the string layout should balance the available roof fields; the final string configuration is confirmed against the per-model MPPT current limits in the datasheet.

    Typical array — with 630 Wp mono-crystalline modules (DC/AC 1.1–1.3):

    Model groupTypical array630 Wp modules
    HPY-SHS-3K-on / 3.6K-on3.3–4.7 kWp6–8
    HPY-SHS-4.2K-on / 5K-on4.6–6.5 kWp8–10
    HPY-SHS-6K-on6.6–7.8 kWp11–13
    HPY-SHS-8K-on8.8–10.4 kWp14–17

    Roof area, orientation and shading decide the final string layout; a larger array also shortens the battery recharge time calculated in the guide above. Figures are typical reference values, not a supply commitment; per-model maximum PV input power is confirmed from the datasheet before ordering.

    Typical Applications

    🏠 Retrofit without a plant room — mount on the exterior wall, keep the interior untouched.
    🌾 Villa, farmhouse & prefab housing — weatherproof operation in remote or dusty locations.
    ⚡ Essential-load backup — refrigeration, lighting, pumps and communications.
    🔄 Residential self-consumption — high-voltage battery for a compact, efficient storage system.

    Other Series in the SHS Range

    SHS Indoor, 3.3–12.3 kW — high-frequency indoor unit for 24 / 48 V gel or lithium battery banks, the lowest cost per kilowatt.
    SHS Outdoor Three-Phase, 4–50 kW — 380 V three-phase output with 1000 V PV input for larger sites and three-phase loads.


    Web: www.bjhpy.com  |  E-mail: info@bjhpy.com

Consult now

Welcome to inquire—we’ll get back to you within one business day. Please keep an eye on your phone or email!

中企跨境-全域组件 制作前进入CSS配置样式

Contact:

Email:

Tel:

WeChat:

在线客服添加返回顶部

右侧在线客服样式 1,2,3 1

图片alt标题设置: Helpyou New Energy

表单验证提示文本: Content cannot be empty!

循环体没有内容时: Sorry,no matching items were found.

CSS / JS 文件放置地