    Series 01 of 03 — Indoor, 24 / 48 V battery platform

    Model codes: HPY-SHS-3.3K-on / 4.3K-on / 6.3K-on / 8.3K-on / 10.3K-on / 12.3K-on

    Choose the indoor series when there is a dry wall, garage or technical room available, and when the battery bank is a 24 V or 48 V gel / lead-acid or lithium pack. High-frequency design keeps the cabinet small and the cost per kilowatt the lowest of the three series — the workhorse of a self-consumption or backup installation.


    System Diagram

    Product Overview

    The HeySun® SHS Indoor Series is the low-voltage member of the SHS hybrid family: a high-frequency, wall-hung inverter rated 3.3 to 12.3 kW that works with an existing 24 V or 48 V battery bank, whether that is a bank of gel / lead-acid blocks or a lithium pack. It accepts PV strings up to 500 V and a utility or generator input, and charges from PV and from the grid with independently programmable current, so the same unit suits a daily-cycle self-consumption system, a priority-driven off-grid installation or a straightforward backup power room.

    Six power steps and dual MPPT trackers on the larger models (8.3 kW and above) make the series equally suitable for a single-family house, a shop, a clinic or a telecom cabinet. Units can be paralleled for higher output, and the inverter will run on PV alone before the battery is installed.

    Key Features

    ⚡ Bidirectional Energy Flow — Solar, battery and grid power the load in any combination; surplus generation charges the battery automatically.
    🔌 10 ms Transfer — Backup-grade changeover keeps essential loads running through outages; output priority is user-configurable.
    📶 Wide MPPT Window — 40–450 V (24 V models) / 80–450 V (48 V models) input, 500 V maximum PV voltage, MPPT efficiency ≥ 99.9%.
    🔊 High-Frequency Design — High power density and compact housing with a full 94% peak efficiency in battery mode.
    👥 Parallel-Ready — Units can be paralleled for higher power as the load grows.
    📱 App Monitoring — RS485 as standard with optional WiFi / GPRS data collector; lithium BMS communication supported.
    🔵 Runs Without Battery — PV-only daytime operation keeps the system productive before batteries are installed.
    🛡️ Configurable Battery Platform — Valve-regulated gel / lead-acid or lithium, with independent PV and utility charge-current settings.

    Technical Specifications

    ModelHPY-SHS-3.3K-onHPY-SHS-4.3K-onHPY-SHS-6.3K-onHPY-SHS-8.3K-onHPY-SHS-10.3K-onHPY-SHS-12.3K-on
    Rated AC output power3300 W4300 W6300 W8300 W10 300 W12 300 W
    Max. PV input power5000 W5000 W7000 W9000 W12 000 W12 000 W
    MPPT voltage range40–450 V40–450 V80–450 V80–450 V80–450 V80–450 V
    Max. PV open-circuit voltage500 V
    Max. PV input current18 A18 A22 A18 A × 222 A × 227 A × 2
    Number of MPPT trackers111222
    Battery voltage24 V (21–30 V)24 V (21–30 V)48 V (42–60 V)48 V (42–60 V)48 V (42–60 V)48 V (42–60 V)
    Battery typeGel / lead-acid or lithium (charge parameters configurable); BMS communication supported
    Max. PV charging current120 A150 A120 A150 A180 A200 A
    Max. utility charging current80 A100 A80 A100 A120 A140 A
    AC output / input voltage220 / 230 / 240 V (output 187–264 V), 50 / 60 Hz, pure sine wave
    Grid input range165–280 V AC (widened 120–280 V AC, configurable); 187–264 V AC in hybrid mode
    Peak efficiency (battery mode)94%
    MPPT efficiency≥ 99.9%
    Transfer time10 ms (typical)
    Display / communicationLCD + LED; RS485, WiFi / GPRS data collector (optional), mobile APP
    Work modesGrid-tied / off-grid / hybrid / backup; output-priority setting
    ProtectionOver-load, short-circuit, over/under-voltage, over-temperature; IP20
    Operating temperature−10 °C to +50 °C; storage −15 °C to +60 °C
    Altitude / humidity2000 m (derating above); 0–95% RH, non-condensing
    Dimensions W×D×H (mm)325 × 275 × 102365 × 297 × 102390 × 320 × 112515 × 365 × 117535 × 462 × 117630 × 540 × 130
    Net weight (kg)66.510.5131723.5

    A dual-output variant with smart load management is available for selected models — contact us for details.

    Battery Sizing Guide

    Platform requirements: 24 V (21–30 V) or 48 V (42–60 V) nominal bank — gel / lead-acid or lithium — sized for the charge and discharge currents of the selected model. Always confirm the battery's continuous discharge rating against the actual load before ordering.

    Three-step sizing:

    1. Night-time energy = daily household consumption × night share (typically about 50%).
    2. Required capacity = night-time energy ÷ depth of discharge ÷ system efficiency (about 0.9). Use DoD 0.9 for LFP, 0.5 for gel / lead-acid.
    3. Check the discharge rate = peak load ÷ (capacity ÷ battery voltage). Compare it with the battery's permitted C-rate; add capacity or apply load management if the rate is too high.

    Typical configuration — residential self-consumption with overnight cover:

    Model groupLFP (DoD 0.9)Gel / lead-acid (DoD 0.5)Typical duty
    HPY-SHS-3.3K-on / 4.3K-on
    (24 V)
    5–10 kWh10–20 kWhApartment or small home, 4–8 kWh overnight
    HPY-SHS-6.3K-on / 8.3K-on
    (48 V)
    10–15 kWh20–30 kWhStandard family home, 8–12 kWh overnight
    HPY-SHS-10.3K-on / 12.3K-on
    (48 V)
    15–30 kWh30–60 kWhLarge home or villa, 12–24 kWh overnight

    Worked example: a household using 16 kWh per day, half of it after sunset, needs 8 ÷ 0.9 ÷ 0.9 ≈ 10 kWh of LFP (or about 18 kWh of gel, a bank that can deliver the peak load within its C-rate).

    The 24 V models draw up to roughly 190 A at full rated load — if the bank sits at the lower end of the range above, confirm a 0.5 C or higher discharge capability. Figures are typical reference values for self-consumption sizing, not a supply commitment; final sizing follows the load calculation for the specific site.

    PV Array Sizing Guide

    Inverter limits: the maximum PV array per model is listed in the specification table above — 5 000 W on the 3.3 / 4.3 kW units, 7 000 W on the 6.3 kW, 9 000 W on the 8.3 kW and 12 000 W on the 10.3 / 12.3 kW units. The absolute maximum PV voltage is 500 V, the MPPT window is 40–450 V (24 V models) or 80–450 V (48 V models), and the larger models (8.3 kW and above) provide two MPPT trackers.

    Three-step sizing:

    1. Required array power = daily consumption ÷ (peak sun hours × performance ratio). Take the performance ratio as 0.75–0.8 and the peak sun hours from local solar data — for example, 16 kWh ÷ (4.5 h × 0.78) ≈ 4.6 kWp.
    2. DC/AC ratio check = array kWp ÷ inverter rated output. Keep the ratio between about 1.0 and 1.3 for all-day harvest, and never above the model's maximum PV input power.
    3. String design — modules in series must keep the open-circuit voltage (calculated at the coldest site temperature) below 500 V; the operating voltage must sit inside the MPPT window; and the string current must not exceed the tracker input current (18 A, 22 A or 27 A per MPPT depending on model).

    Typical array — with 630 Wp mono-crystalline modules:

    Model groupMax. PV input powerTypical array630 Wp modules
    HPY-SHS-3.3K-on / 4.3K-on5 000 W4–5 kWp7–8
    HPY-SHS-6.3K-on7 000 W5–7 kWp8–11
    HPY-SHS-8.3K-on9 000 W6–9 kWp10–14
    HPY-SHS-10.3K-on / 12.3K-on12 000 W8–12 kWp13–19

    Roof area, orientation and shading decide the final string layout; a larger array also shortens the battery recharge time calculated in the guide above. Figures are typical reference values, not a supply commitment.

    Typical Applications

    🏠 Whole-home backup — essential loads ride through grid failures with 10 ms transfer.
    🏫 Self-consumption — configurable output-priority strategies.
    🏢 Shops & small business — 6.3–12.3 kW steps with dual MPPT trackers.
    📡 Clinics, telecom & critical loads — gel or lithium battery bank with BMS communication.

    Other Series in the SHS Range

    SHS Outdoor Single-Phase, 3–8 kW — the same hybrid platform for exterior walls: IP65 housing, high-voltage lithium battery, no technical room needed.
    SHS Outdoor Three-Phase, 4–50 kW — 380 V three-phase output with 1000 V PV input for larger premises and three-phase loads.


    Web: www.bjhpy.com  |  E-mail: info@bjhpy.com

Consult now

Welcome to inquire—we’ll get back to you within one business day. Please keep an eye on your phone or email!

中企跨境-全域组件 制作前进入CSS配置样式

Contact:

Email:

Tel:

WeChat:

在线客服添加返回顶部

右侧在线客服样式 1,2,3 1

图片alt标题设置: Helpyou New Energy

表单验证提示文本: Content cannot be empty!

循环体没有内容时: Sorry,no matching items were found.

CSS / JS 文件放置地