Share
HeySun® SHS Indoor Series — Hybrid Solar Inverter 3.3–12.3 kW
Category:
Residential PV System
Keywords:
- Product Description
-
HeySun® SHS Indoor Series — Hybrid Solar Inverter 3.3–12.3 kW
Series 01 of 03 — Indoor, 24 / 48 V battery platform
Model codes: HPY-SHS-3.3K-on / 4.3K-on / 6.3K-on / 8.3K-on / 10.3K-on / 12.3K-on
Choose the indoor series when there is a dry wall, garage or technical room available, and when the battery bank is a 24 V or 48 V gel / lead-acid or lithium pack. High-frequency design keeps the cabinet small and the cost per kilowatt the lowest of the three series — the workhorse of a self-consumption or backup installation.
System Diagram

Product Overview
The HeySun® SHS Indoor Series is the low-voltage member of the SHS hybrid family: a high-frequency, wall-hung inverter rated 3.3 to 12.3 kW that works with an existing 24 V or 48 V battery bank, whether that is a bank of gel / lead-acid blocks or a lithium pack. It accepts PV strings up to 500 V and a utility or generator input, and charges from PV and from the grid with independently programmable current, so the same unit suits a daily-cycle self-consumption system, a priority-driven off-grid installation or a straightforward backup power room.
Six power steps and dual MPPT trackers on the larger models (8.3 kW and above) make the series equally suitable for a single-family house, a shop, a clinic or a telecom cabinet. Units can be paralleled for higher output, and the inverter will run on PV alone before the battery is installed.
Key Features
⚡ Bidirectional Energy Flow — Solar, battery and grid power the load in any combination; surplus generation charges the battery automatically.
🔌 10 ms Transfer — Backup-grade changeover keeps essential loads running through outages; output priority is user-configurable.
📶 Wide MPPT Window — 40–450 V (24 V models) / 80–450 V (48 V models) input, 500 V maximum PV voltage, MPPT efficiency ≥ 99.9%.
🔊 High-Frequency Design — High power density and compact housing with a full 94% peak efficiency in battery mode.
👥 Parallel-Ready — Units can be paralleled for higher power as the load grows.
📱 App Monitoring — RS485 as standard with optional WiFi / GPRS data collector; lithium BMS communication supported.
🔵 Runs Without Battery — PV-only daytime operation keeps the system productive before batteries are installed.
🛡️ Configurable Battery Platform — Valve-regulated gel / lead-acid or lithium, with independent PV and utility charge-current settings.Technical Specifications
Model HPY-SHS-3.3K-on HPY-SHS-4.3K-on HPY-SHS-6.3K-on HPY-SHS-8.3K-on HPY-SHS-10.3K-on HPY-SHS-12.3K-on Rated AC output power 3300 W 4300 W 6300 W 8300 W 10 300 W 12 300 W Max. PV input power 5000 W 5000 W 7000 W 9000 W 12 000 W 12 000 W MPPT voltage range 40–450 V 40–450 V 80–450 V 80–450 V 80–450 V 80–450 V Max. PV open-circuit voltage 500 V Max. PV input current 18 A 18 A 22 A 18 A × 2 22 A × 2 27 A × 2 Number of MPPT trackers 1 1 1 2 2 2 Battery voltage 24 V (21–30 V) 24 V (21–30 V) 48 V (42–60 V) 48 V (42–60 V) 48 V (42–60 V) 48 V (42–60 V) Battery type Gel / lead-acid or lithium (charge parameters configurable); BMS communication supported Max. PV charging current 120 A 150 A 120 A 150 A 180 A 200 A Max. utility charging current 80 A 100 A 80 A 100 A 120 A 140 A AC output / input voltage 220 / 230 / 240 V (output 187–264 V), 50 / 60 Hz, pure sine wave Grid input range 165–280 V AC (widened 120–280 V AC, configurable); 187–264 V AC in hybrid mode Peak efficiency (battery mode) 94% MPPT efficiency ≥ 99.9% Transfer time 10 ms (typical) Display / communication LCD + LED; RS485, WiFi / GPRS data collector (optional), mobile APP Work modes Grid-tied / off-grid / hybrid / backup; output-priority setting Protection Over-load, short-circuit, over/under-voltage, over-temperature; IP20 Operating temperature −10 °C to +50 °C; storage −15 °C to +60 °C Altitude / humidity 2000 m (derating above); 0–95% RH, non-condensing Dimensions W×D×H (mm) 325 × 275 × 102 365 × 297 × 102 390 × 320 × 112 515 × 365 × 117 535 × 462 × 117 630 × 540 × 130 Net weight (kg) 6 6.5 10.5 13 17 23.5 A dual-output variant with smart load management is available for selected models — contact us for details.
Battery Sizing Guide
Platform requirements: 24 V (21–30 V) or 48 V (42–60 V) nominal bank — gel / lead-acid or lithium — sized for the charge and discharge currents of the selected model. Always confirm the battery's continuous discharge rating against the actual load before ordering.
Three-step sizing:
- Night-time energy = daily household consumption × night share (typically about 50%).
- Required capacity = night-time energy ÷ depth of discharge ÷ system efficiency (about 0.9). Use DoD 0.9 for LFP, 0.5 for gel / lead-acid.
- Check the discharge rate = peak load ÷ (capacity ÷ battery voltage). Compare it with the battery's permitted C-rate; add capacity or apply load management if the rate is too high.
Typical configuration — residential self-consumption with overnight cover:
Model group LFP (DoD 0.9) Gel / lead-acid (DoD 0.5) Typical duty HPY-SHS-3.3K-on / 4.3K-on
(24 V)5–10 kWh 10–20 kWh Apartment or small home, 4–8 kWh overnight HPY-SHS-6.3K-on / 8.3K-on
(48 V)10–15 kWh 20–30 kWh Standard family home, 8–12 kWh overnight HPY-SHS-10.3K-on / 12.3K-on
(48 V)15–30 kWh 30–60 kWh Large home or villa, 12–24 kWh overnight Worked example: a household using 16 kWh per day, half of it after sunset, needs 8 ÷ 0.9 ÷ 0.9 ≈ 10 kWh of LFP (or about 18 kWh of gel, a bank that can deliver the peak load within its C-rate).
The 24 V models draw up to roughly 190 A at full rated load — if the bank sits at the lower end of the range above, confirm a 0.5 C or higher discharge capability. Figures are typical reference values for self-consumption sizing, not a supply commitment; final sizing follows the load calculation for the specific site.
PV Array Sizing Guide
Inverter limits: the maximum PV array per model is listed in the specification table above — 5 000 W on the 3.3 / 4.3 kW units, 7 000 W on the 6.3 kW, 9 000 W on the 8.3 kW and 12 000 W on the 10.3 / 12.3 kW units. The absolute maximum PV voltage is 500 V, the MPPT window is 40–450 V (24 V models) or 80–450 V (48 V models), and the larger models (8.3 kW and above) provide two MPPT trackers.
Three-step sizing:
- Required array power = daily consumption ÷ (peak sun hours × performance ratio). Take the performance ratio as 0.75–0.8 and the peak sun hours from local solar data — for example, 16 kWh ÷ (4.5 h × 0.78) ≈ 4.6 kWp.
- DC/AC ratio check = array kWp ÷ inverter rated output. Keep the ratio between about 1.0 and 1.3 for all-day harvest, and never above the model's maximum PV input power.
- String design — modules in series must keep the open-circuit voltage (calculated at the coldest site temperature) below 500 V; the operating voltage must sit inside the MPPT window; and the string current must not exceed the tracker input current (18 A, 22 A or 27 A per MPPT depending on model).
Typical array — with 630 Wp mono-crystalline modules:
Model group Max. PV input power Typical array 630 Wp modules HPY-SHS-3.3K-on / 4.3K-on 5 000 W 4–5 kWp 7–8 HPY-SHS-6.3K-on 7 000 W 5–7 kWp 8–11 HPY-SHS-8.3K-on 9 000 W 6–9 kWp 10–14 HPY-SHS-10.3K-on / 12.3K-on 12 000 W 8–12 kWp 13–19 Roof area, orientation and shading decide the final string layout; a larger array also shortens the battery recharge time calculated in the guide above. Figures are typical reference values, not a supply commitment.
Typical Applications
🏠 Whole-home backup — essential loads ride through grid failures with 10 ms transfer.
🏫 Self-consumption — configurable output-priority strategies.
🏢 Shops & small business — 6.3–12.3 kW steps with dual MPPT trackers.
📡 Clinics, telecom & critical loads — gel or lithium battery bank with BMS communication.Other Series in the SHS Range
SHS Outdoor Single-Phase, 3–8 kW — the same hybrid platform for exterior walls: IP65 housing, high-voltage lithium battery, no technical room needed.
SHS Outdoor Three-Phase, 4–50 kW — 380 V three-phase output with 1000 V PV input for larger premises and three-phase loads.Web: www.bjhpy.com | E-mail: info@bjhpy.com
Consult now
Welcome to inquire—we’ll get back to you within one business day. Please keep an eye on your phone or email!
More recommendations
Add: No. 22 Tengren Road, Shunyi District, Beijing
Email: info@bjhpy.com
Consultation Hotline:
86-010-60480298
Follow us
Contact:
Email:
Tel:
WeChat:
在线客服添加返回顶部
右侧在线客服样式 1,2,3 1
图片alt标题设置: Helpyou New Energy
表单验证提示文本: Content cannot be empty!