HeyHybrid® 煜合® Series | HeyHybrid Three — Hybrid Energy Storage Inverter Platform
HeyHybrid Three — Three-Phase High-Voltage Hybrid Inverter — 5–10 kW
Model range: HPY-HTP-5K-30 · HPY-HTP-6K-30 · HPY-HTP-8K-30 · HPY-HTP-9.9K-30 · HPY-HTP-10K-30
110% unbalanced output · 160% backup @10 s · IP66 · up to 10 units in parallel
Residential | Three-Phase | HV Battery | 2 MPPTs
Product Overview
The HPY-HTP 5–10 kW series brings three-phase hybrid capability to residential and light-commercial buildings. Two MPPTs with 20 A per string handle complex roofs with two orientations, while the 30 A battery port charges and discharges at the full rated power.
The series supports 110% unbalanced output between phases — a decisive advantage for real houses where loads are never evenly distributed. In backup mode it delivers up to 160% of rated power for 10 seconds to start motor loads, and supports half-wave loads without tripping.
With IP66 protection and fanless operation the inverter mounts outdoors in any weather. Up to ten units can be paralleled for larger three-phase systems, managed through the built-in station-level energy management.
Key Features
110% unbalanced output — Phase loads may fully imbalance — no derating in real installations.
160% backup @10 s — Starts pumps, compressors and other motor loads in backup mode.
2 MPPT · 20 A per string — Two roof orientations, high-current modules, no string clipping.
30 A battery current — Full-power charge and discharge on every model.
IP66 outdoor — Sealed enclosure, fanless and silent.
10-unit parallel — Scales from 5 kW to 100 kW three-phase systems.
Half-wave load support — Runs hair dryers and simple rectifier loads without issues.
Diesel generator compatible — Adds a generator input for weak-grid sites.Model Range
Specification HPY-HTP-5K-30 HPY-HTP-6K-30 HPY-HTP-8K-30 HPY-HTP-9.9K-30 HPY-HTP-10K-30 Rated AC output power 5.0 6.0 8.0 9.9 10.0 Max. PV array power 10 kWp 12 kWp 16 kWp 20 kWp 20 kWp No. of MPP trackers 2 2 2 2 2 Max. charge / discharge current 30/30 30/30 30/30 30/30 30/30 Battery voltage range 130-750 V Max. efficiency 97.7% Dimensions (W×H×D) 505x460x207 mm Weight 26.5 kg Ingress protection IP66 All models share one mechanical platform, so a project can standardise on one product family across power classes.
Electrical Specifications
PV Input
Specification HPY-HTP-5K-30 HPY-HTP-6K-30 HPY-HTP-8K-30 HPY-HTP-9.9K-30 HPY-HTP-10K-30 Max. PV Array Power 10 12 16 20 20 Max. PV Input Voltage * 1000* Rated PV Input Voltage 620 Start-up Voltage 135 MPPT Operating Voltage Range * 125-950* No. of MPP Trackers 2 No. of Strings per MPPT 1/1 Max. Input Current per MPPT 20/20 Max. Short-circuit Current per MPPT 30/30 Battery
Specification HPY-HTP-5K-30 HPY-HTP-6K-30 HPY-HTP-8K-30 HPY-HTP-9.9K-30 HPY-HTP-10K-30 Battery Type Lithium-ion Battery Voltage Range 130-750 No. of Battery Input 1 Max. Charging/Discharging Current 30/30 Max. Charging/Discharging Power 7.5/5 9/6 12/8 14.9/9.9 15/10 Grid Side (On-Grid)
Specification HPY-HTP-5K-30 HPY-HTP-6K-30 HPY-HTP-8K-30 HPY-HTP-9.9K-30 HPY-HTP-10K-30 Rated Output Power 5.0 6.0 8.0 9.9 10.0 Max. Output Apparent Power 5.0 6.0 8.0 9.9 10.0 Rated AC Voltage 3L/N/PE; 220/380V;230/400V;240/415V Rated AC Frequency 50/60 Rated Output Current 7.6/7.2/6.9 9.1/8.7/8.3 12.1/11.6/11.1 15/14.3/13.8 15.2/14.5/13.9 Max. Output Current 7.6 9.1 12.1 15.0 15.2 Power Factor 0.8 leading …0.8 lagging THDi (@Rated Power) <3% Max. Input Apparent Power ** 10.0 12.0 12.0 14.9 15.0 Rated AC Voltage 3L/N/PE; 220/380V;230/400V;240/415V Rated AC Frequency 50/60 Max. AC Input Current 15.2 18.2 18.2 22.5 22.7 Back-up Side (Off-Grid)
Specification HPY-HTP-5K-30 HPY-HTP-6K-30 HPY-HTP-8K-30 HPY-HTP-9.9K-30 HPY-HTP-10K-30 Rated Output Power 5.0 6.0 8.0 9.9 10.0 Peak Output Apparent Power 9.6 @10s 9.6 @10s 16 @10s 16 @10s 16 @10s Rated AC Voltage 3L/N/PE; 220/380V;230/400V;240/415V Rated Output Frequency 50/60 Rated Output Current 7.6/7.2/6.9 9.1/8.7/8.3 12.1/11.6/11.1 15/14.3/13.8 15.2/14.5/13.9 On/Off-grid Switching Time < 10ms THDv (@Linear Load) <3% Efficiency
Specification HPY-HTP-5K-30 HPY-HTP-6K-30 HPY-HTP-8K-30 HPY-HTP-9.9K-30 HPY-HTP-10K-30 MPPT Efficiency 99.9% Max. Efficiency 97.7% European Efficiency 97.0% Protection
Integrated protection — DC reverse polarity protection / battery input reverse-connection protection / insulation resistance protection / surge protection (DC: Type II, AC: Type II) / over-temperature protection / residual current protection / anti-islanding protection / AC over-voltage protection / overload protection / AC short-circuit protection
General Data
Specification HPY-HTP-5K-30 HPY-HTP-6K-30 HPY-HTP-8K-30 HPY-HTP-9.9K-30 HPY-HTP-10K-30 Dimensions [W×H×D mm] 505x460x207 Weight 26.5 Ingress Protection IP66 Standby Self-consumption <25 Topology Transformerless Operating Temperature Range -30~60 Relative Humidity 0~100 Max. Operation Altitude 3000 Over Voltage Category II(PV+Battery), III(Mains) Cooling Natural Convection Noise Level < 25 Display LED & OLED Communication CAN, RS485 * Max. PV input voltage is 950 V; beyond it the inverter enters standby.
** Max. input apparent power means the maximum power imported from the grid used to supply backup loads and charge the battery.HEPUYU New Energy | No. 22 Tengren Road, Shunyi District, Beijing, China | www.bjhpy.com | info@bjhpy.com
Specifications subject to change without notice. The binding specification is that of the delivered batch; contact us for the current datasheet.
Consult now
Welcome to inquire—we’ll get back to you within one business day. Please keep an eye on your phone or email!
More recommendations
Add: No. 22 Tengren Road, Shunyi District, Beijing
Email: info@bjhpy.com
Consultation Hotline:
86-010-60480298
Follow us
Contact:
Email:
Tel:
WeChat:
在线客服添加返回顶部
右侧在线客服样式 1,2,3 1
图片alt标题设置: Helpyou New Energy
表单验证提示文本: Content cannot be empty!
循环体没有内容时: Sorry,no matching items were found.
CSS / JS 文件放置地