• Three-Phase High-Voltage Hybrid Inverter — 10–30 kW, Dual Battery Ports
Three-Phase High-Voltage Hybrid Inverter — 10–30 kW, Dual Battery Ports
+

Share

Three-Phase High-Voltage Hybrid Inverter — 10–30 kW, Dual Battery Ports

Three-phase hybrid inverter from 10 to 30 kW with 4 MPPTs and dual independent 40 A battery ports (80 A total). 200% peak backup output, <10 ms switchover, native generator control and 15-minute dynamic pricing. HEPUYU New Energy.

Consult now


Category:

Hybrid Inverter

Keywords:

  • Product Description
  • HeyHybrid® 煜合® Series | HeyHybrid Three — Hybrid Energy Storage Inverter Platform

    HeyHybrid Three — Three-Phase High-Voltage Hybrid Inverter — 10–30 kW, Dual Battery Ports

    Model range: HPY-HTP-9.9K-80 · HPY-HTP-10K-80 · HPY-HTP-15K-80 · HPY-HTP-20K-80 · HPY-HTP-24.9K-80 · HPY-HTP-25K-80 · HPY-HTP-29.9K-80 · HPY-HTP-30K-80

    Dual 40 A battery ports (80 A total) · 200% peak backup · 4 MPPTs for complex roofs

    Commercial | Three-Phase | HV Battery | 4 MPPTs


    Product Overview

    The HPY-HTP 10–30 kW series is built for commercial rooftops with complex geometry: four independent MPPTs master four roof planes, and a 120 V start-up voltage extends generation into the early morning and late afternoon.

    Two independent battery ports — 40 A each, 80 A combined — allow two separate battery blocks to be charged and discharged simultaneously, doubling usable storage power without additional hardware. Up to 200% peak backup output drives inductive loads during outages.

    The series includes native generator control for continuous on-grid supply in weak-grid areas, 120% surge capacity for 60 seconds for heavy loads, and profits from 15-minute dynamic pricing through the built-in energy management — with smart-load control and half-wave load handling included.

    Key Features

    Dual 40 A battery ports — Two independent battery blocks, 80 A total charging power.
    4 MPPTs · 20 A per string — Complex roofs with four orientations — no compromises.
    120 V low start-up — More generation hours every day.
    200% peak backup output — Drives inductive loads during grid failures.
    120% surge for 60 s — Secures heavy loads through extended surges.
    Native generator control — Generator input for continuous supply in weak grids.
    10-unit parallel — Scales up to 300 kW.
    15-min dynamic pricing — Profits from modern electricity markets.

    Model Range

    SpecificationHPY-HTP-9.9K-80HPY-HTP-10K-80HPY-HTP-15K-80HPY-HTP-20K-80HPY-HTP-24.9K-80HPY-HTP-25K-80HPY-HTP-29.9K-80HPY-HTP-30K-80
    Rated AC output power9.910.015.020.024.925.029.930.0
    Max. PV array power20 kWp20 kWp30 kWp40 kWp50 kWp50 kWp50 kWp50 kWp
    No. of MPP trackers44444444
    Max. charge / discharge current40*2/40*240*2/40*240*2/40*240*2/40*240*2/40*240*2/40*240*2/40*240*2/40*2
    Battery voltage range130-850 V
    Max. efficiency97.60%
    Dimensions (W×H×D)587×535×238 mm
    Weight38.5 kg
    Ingress protectionIP66

    All models share one mechanical platform, so a project can standardise on one product family across power classes.

    Electrical Specifications

    PV Input

    SpecificationHPY-HTP-9.9K-80HPY-HTP-10K-80HPY-HTP-15K-80HPY-HTP-20K-80HPY-HTP-24.9K-80HPY-HTP-25K-80HPY-HTP-29.9K-80HPY-HTP-30K-80
    Max. PV Array Power2020304050505050
    Max. PV Input Voltage *1000
    Rated PV Input Voltage620
    Start-up Voltage120
    MPPT Operating Voltage Range *120-950
    No. of MPP Trackers4
    No. of Strings per MPPT1/1/1/1
    Max. Input Current per MPPT20/20/20/20
    Max. Short-circuit Current per MPPT25/25/25/25

    Battery

    SpecificationHPY-HTP-9.9K-80HPY-HTP-10K-80HPY-HTP-15K-80HPY-HTP-20K-80HPY-HTP-24.9K-80HPY-HTP-25K-80HPY-HTP-29.9K-80HPY-HTP-30K-80
    Battery TypeLithium Battery (with BMS)
    Battery Voltage Range130-850
    No. of Battery Input2
    Max. Charging/Discharging Current40*2/40*2
    Max. Charging/Discharging Power9.9/9.910/1015/1520/2024.9/24.925/2529.9/29.930/30

    Grid Side (On-Grid)

    SpecificationHPY-HTP-9.9K-80HPY-HTP-10K-80HPY-HTP-15K-80HPY-HTP-20K-80HPY-HTP-24.9K-80HPY-HTP-25K-80HPY-HTP-29.9K-80HPY-HTP-30K-80
    Rated Output Power9.910.015.020.024.925.029.930.0
    Max. Output Apparent Power9.910.015.020.024.925.029.930.0
    Rated AC Voltage3L/N/PE; 220/380V;230/400V;240/415V
    Rated AC Frequency50/60
    Rated Output Current15.2/14.5/13.915.2/14.5/13.922.7/21.7/20.830.3/29/27.837.7/36.1/34.637.9/36.2/34.745.3/43.3/41.545.5/43.5/41.7
    Max. Output Current17.617.626.235.043.543.852.352.6
    Power Factor0.8 leading …0.8 lagging
    THDi (@Rated Power)<3%
    Max. Input Apparent Power**20.020.030.040.050.050.060.060.0
    Rated AC Voltage3L/N/PE; 220/380V;230/400V;240/415V
    Rated AC Frequency50/60
    Max. AC Input Current30.330.345.560.675.875.890.990.9

    Back-up Side (Off-Grid)

    SpecificationHPY-HTP-9.9K-80HPY-HTP-10K-80HPY-HTP-15K-80HPY-HTP-20K-80HPY-HTP-24.9K-80HPY-HTP-25K-80HPY-HTP-29.9K-80HPY-HTP-30K-80
    Rated Output Power9.910.015.020.024.925.029.930
    Peak Output Apparent Power24 @10s24 @10s24 @10s48 @10s48 @10s48 @10s48 @10s48 @10s
    Rated AC Voltage3L/N/PE; 220/380V;230/400V;240/415V
    Rated Output Frequency50/60
    Rated Output Current15.2/14.5/13.915.2/14.5/13.922.7/21.7/20.830.3/29/27.837.7/36.1/34.637.9/36.2/34.745.3/43.3/41.545.5/43.5/41.7
    On/Off-grid Switching Time< 10ms
    THDv (@Linear Load)<3%

    Generator Side

    SpecificationHPY-HTP-9.9K-80HPY-HTP-10K-80HPY-HTP-15K-80HPY-HTP-20K-80HPY-HTP-24.9K-80HPY-HTP-25K-80HPY-HTP-29.9K-80HPY-HTP-30K-80
    Max. Input Apparent Power12.012.018.024.029.930.035.936.0
    Rated Input Voltage3L/N/PE; 220/380V;230/400V;240/415V
    Rated Input Frequency50/60
    Max. Input Current18.218.227.336.445.345.554.454.5

    Efficiency

    SpecificationHPY-HTP-9.9K-80HPY-HTP-10K-80HPY-HTP-15K-80HPY-HTP-20K-80HPY-HTP-24.9K-80HPY-HTP-25K-80HPY-HTP-29.9K-80HPY-HTP-30K-80
    MPPT Efficiency99.90%
    Max. Efficiency97.60%
    European Efficiency97.10%

    Protection

    Integrated protection — DC reverse polarity protection / battery input reverse-connection protection / insulation resistance protection / surge protection (DC: Type II, AC: Type II) / over-temperature protection / residual current protection / anti-islanding protection / AC over-voltage protection / overload protection / AC short-circuit protection

    General Data

    SpecificationHPY-HTP-9.9K-80HPY-HTP-10K-80HPY-HTP-15K-80HPY-HTP-20K-80HPY-HTP-24.9K-80HPY-HTP-25K-80HPY-HTP-29.9K-80HPY-HTP-30K-80
    Dimensions [W×H×D mm]587×535×238
    Weight38.5
    Ingress ProtectionIP66
    Standby Self-consumption<35
    TopologyTransformerless
    Operating Temperature Range-30~60
    Relative Humidity0~100
    Max. Operation Altitude3000
    Over Voltage CategoryII(PV+Battery), III(Mains+Backup)
    CoolingSmart Fan
    DisplayLED & OLED
    CommunicationCAN, RS485

    ** Max. input apparent power means the maximum power imported from the grid used to supply backup loads and charge the battery.


    HEPUYU New Energy | No. 22 Tengren Road, Shunyi District, Beijing, China | www.bjhpy.com | info@bjhpy.com

    Specifications subject to change without notice. The binding specification is that of the delivered batch; contact us for the current datasheet.

Consult now

Welcome to inquire—we’ll get back to you within one business day. Please keep an eye on your phone or email!

中企跨境-全域组件 制作前进入CSS配置样式

Contact:

Email:

Tel:

WeChat:

在线客服添加返回顶部

右侧在线客服样式 1,2,3 1

图片alt标题设置: Helpyou New Energy

表单验证提示文本: Content cannot be empty!

循环体没有内容时: Sorry,no matching items were found.

CSS / JS 文件放置地