• Three-Phase High-Voltage Hybrid Inverter — 25–50 kW, 150 A (Gen 2)
Three-Phase High-Voltage Hybrid Inverter — 25–50 kW, 150 A (Gen 2)
+

Share

Three-Phase High-Voltage Hybrid Inverter — 25–50 kW, 150 A (Gen 2)

Second-generation three-phase hybrid inverter 25-50 kW with 150 A battery current, 4 MPPTs at 40 A per string, 200% DC oversizing, 100% unbalanced output, 150% backup and IP66 protection. HEPUYU New Energy.

Consult now


Category:

Hybrid Inverter

Keywords:

  • Product Description
  • HeyHybrid® 煜合® Series | HeyHybrid Pro — Hybrid Energy Storage Inverter Platform

    HeyHybrid Pro — Three-Phase High-Voltage Hybrid Inverter — 25–50 kW, 150 A (Gen 2)

    Model range: HPY-HPP-25K-150 · HPY-HPP-29.9K-150 · HPY-HPP-30K-150 · HPY-HPP-40K-150 · HPY-HPP-50K-150

    150 A battery current · 200% grid input · 100% unbalanced output · IP66

    Commercial & Industry | Three-Phase | HV Battery | 4 MPPTs


    Product Overview

    The HPY-HPP 25–50 kW series is the second generation of our C&I hybrid line, and the step change is battery power: 150 A of charge and discharge current turns the inverter into a full-power storage hub for demanding industrial cycles.

    The PV side accepts up to 200% DC oversizing with 40 A per MPPT string, so existing module fleets can be re-used when a site upgrades from grid-tied to hybrid. In backup mode the series delivers 150% of rated power for 10 seconds and supports 100% three-phase unbalanced output.

    With up to 200% grid input power for fast battery replenishment, precise export limitation, third-party EMS/BMS compatibility and IP66 protection, this series fits both new industrial storage plants and retrofits of existing PV systems.

    Key Features

    150 A charge / discharge — High-current battery cycling for daily arbitrage.
    200% DC oversizing — Re-uses oversized arrays from existing PV plants.
    40 A per MPPT string — Modern high-current modules, four strings groups.
    150% backup @10 s — Covers industrial motor starting.
    100% unbalanced output — Full power on a single phase if the plant demands.
    200% grid input — Fast battery recharge from the grid when tariffs allow.
    Third-party EMS & BMS — Integrates with plant-level control systems.
    IP66 outdoor — Sealed for dusty and coastal industrial environments.

    Model Range

    SpecificationHPY-HPP-25K-150HPY-HPP-29.9K-150HPY-HPP-30K-150HPY-HPP-40K-150HPY-HPP-50K-150
    Rated AC output power25.029.930.040.050.0
    Max. PV array power50 kWp60 kWp60 kWp80 kWp100 kWp
    No. of MPP trackers44444
    Max. charge / discharge current150/150150/150150/150150/150150/150
    Battery voltage range150-840 V
    Max. efficiency97.80%
    Dimensions (W×H×D)919x739x305 mm
    Weight89 kg
    Ingress protectionIP66

    All models share one mechanical platform, so a project can standardise on one product family across power classes.

    Electrical Specifications

    PV Input

    SpecificationHPY-HPP-25K-150HPY-HPP-29.9K-150HPY-HPP-30K-150HPY-HPP-40K-150HPY-HPP-50K-150
    Max. PV Array Power50606080100
    Max. PV Input Voltage *1000*
    Rated PV Input Voltage620
    Start-up Voltage135
    MPPT Operating Voltage Range *200-950*
    No. of MPP Trackers4
    No. of Strings per MPPT2/2/2/2
    Max. Input Current per MPPT40/40/40/40
    Max. Short-circuit Current per MPPT50/50/50/50

    Battery

    SpecificationHPY-HPP-25K-150HPY-HPP-29.9K-150HPY-HPP-30K-150HPY-HPP-40K-150HPY-HPP-50K-150
    Battery TypeLithium-ion
    Battery Voltage Range150-840
    No. of Battery Input1
    Max. Charge/Discharge Current150/150
    Max. Charge/Discharge Power25/2530/3030/3040/4050/50

    Grid Side (On-Grid)

    SpecificationHPY-HPP-25K-150HPY-HPP-29.9K-150HPY-HPP-30K-150HPY-HPP-40K-150HPY-HPP-50K-150
    Rated Output Power25.029.930.040.050.0
    Max. Output Apparent Power25.029.930.040.050.0
    Rated AC Voltage3L/N/PE; 220/380V; 230/400V; 240/415V
    Rated AC Frequency50/60
    Rated Output Current37.9/36.2/34.745.3/43.3/41.545.5/43.5/41.760.6/58/55.675.8/72.5/69.4
    Max. Output Current37.945.345.560.675.8
    Power Factor0.8 leading …0.8 lagging
    THDi (@Rated Power)<3%
    Max. Input Apparent Power **50.059.860.080.080.0
    Rated AC Voltage3L/N/PE; 220/380V; 230/400V; 240/415V
    Rated AC Frequency50/60
    Max. AC Input Current75.890.690.9121.2121.2

    Back-up Side (Off-Grid)

    SpecificationHPY-HPP-25K-150HPY-HPP-29.9K-150HPY-HPP-30K-150HPY-HPP-40K-150HPY-HPP-50K-150
    Rated Output Power25.029.930.040.050.0
    Peak Output Apparent Power37.5 @10s45 @10s45 @10s60 @10s75 @10s
    Rated Output Voltage3L/N/PE; 220/380V; 230/400V; 240/415V
    Rated Output Frequency50/60
    Rated Output Current37.9/36.2/34.745.3/43.3/41.545.5/43.5/41.760.6/58/55.675.8/72.5/69.4
    On/Off-grid Switching Time< 10ms
    THDv (@Linear Load)<3%

    Generator Side

    SpecificationHPY-HPP-25K-150HPY-HPP-29.9K-150HPY-HPP-30K-150HPY-HPP-40K-150HPY-HPP-50K-150
    Max. Input Apparent Power2529.9304050
    Rated Input Voltage3L/N/PE; 220/380V; 230/400V; 240/415V
    Rated Input Frequency50/60
    Max. Input Current37.945.345.560.675.8

    Efficiency

    SpecificationHPY-HPP-25K-150HPY-HPP-29.9K-150HPY-HPP-30K-150HPY-HPP-40K-150HPY-HPP-50K-150
    MPPT Efficiency99.90%
    Max. Efficiency97.80%
    European Efficiency97.20%
    Max. Battery to AC Efficiency98.50%
    Max. PV to Battery Efficiency97.50%

    Protection

    Integrated protection — DC reverse polarity protection / battery input reverse-connection protection / insulation resistance protection / surge protection (DC: Type II, AC: Type II) / over-temperature protection / residual current protection / anti-islanding protection / AC over-voltage protection / overload protection / AC short-circuit protection

    General Data

    SpecificationHPY-HPP-25K-150HPY-HPP-29.9K-150HPY-HPP-30K-150HPY-HPP-40K-150HPY-HPP-50K-150
    Dimensions [W×H×D mm]919x739x305
    Weight89
    Ingress ProtectionIP66
    Standby Self-consumption< 40
    TopologyTransformerless
    Operating Temperature Range-30~60
    Relative Humidity0~100
    Max. Operation Altitude3000
    Over Voltage CategoryII(PV+Battery), III(Mains)
    CoolingSmart Fan
    Noise Level< 65
    DisplayLED & OLED
    CommunicationCAN, RS485

    * Max. PV input voltage is 950 V; beyond it the inverter enters standby.
    ** Max. input apparent power means the maximum power imported from the grid used to supply backup loads and charge the battery.


    HEPUYU New Energy | No. 22 Tengren Road, Shunyi District, Beijing, China | www.bjhpy.com | info@bjhpy.com

    Specifications subject to change without notice. The binding specification is that of the delivered batch; contact us for the current datasheet.

Consult now